News centres

Home > News > Industry Trends > pvd coating machine diffusion pump repair and maintenance

pvd coating machine diffusion pump repair and maintenance

2023-11-28

170
Share

The diffusion pump is a very important component of the pvd coating machine. As we all know, the pvd coating machine works in a vacuum state, so in order for the vacuum chamber to reach vacuum, the diffusion pump is indispensable. However, to ensure the long-term stable operation of the pvd coating machine, diffusion pump care and maintenance are essential. Below, the editor of Huicheng Vacuum will give you a detailed introduction to the care and maintenance knowledge of vacuum coating machines. I hope it can help you:


pvd coating machine


1. The cooling water must be kept flowing smoothly during the operation of the diffusion pump. After stopping heating, the cooling water must be turned off only after the pump working fluid has been completely cooled.
2. When the diffusion pump stops working, the vacuum should be maintained in the pump to prevent the pump oil from deteriorating.
3. The gas to be pumped should be dry, non-corrosive and dust-free.
4. If the diffusion pump is not used temporarily, it should be kept in a vacuum state during storage to avoid pump oil contamination and corrosion of various parts, and the remaining water in the cooling water jacket should be blown away. The room temperature maintained at the site should be between 10-40 degrees Celsius.
5. The performance of the diffusion pump will gradually deteriorate after long-term operation and should be checked regularly. For example: if the pump oil is reduced or oxidized, refuel or replace it according to the corresponding requirements; the parts and pump cavity are first cleaned with aviation gasoline, then scrubbed with acetone, and dried at 80-100 degrees Celsius or dried with a hair dryer. . After processing, assemble in sequence, keeping the pump core and pump bottom vertical and concentric with the pump chamber, and the nozzle clearances at all levels should be adjusted according to the original requirements.
6. After the water has evaporated, install the pump core, add new diffusion pump oil, reinstall the body, connect the water pipes, install the electric stove, and then restart the machine.
7. Pay attention to leak detection before restarting the machine. The method is: start the maintenance pump, close the vacuum chamber door, and after a few minutes, observe whether the vacuum degree is 6*10 0 Pa. Otherwise, a leak test is required to check whether the sealing ring is missing at the connection or the sealing ring is crushed. Heating can only be done after eliminating the risk of air leakage, otherwise the diffusion pump oil will burn out and cannot enter working condition.
Proper maintenance of the diffusion pump of the pvd coating machine is directly related to production efficiency and production costs.
We use cookies
We use cookies and other tracking technologies to improve your browsing experience on our website to show you personalized content and targeted ads, to analyze our website traffic, and to understand where our visitors are coming from. please consult our Cookie Policy.